Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | Standby |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Characteristics
• lithium battery support with longer backup time
Structure simple and reliable, low failure rate, small volume, low noise
• Multiple protection functions better protect your devices
If the power supply system (including UPS) fails, it will provide a comprehensive
protection, and protect against overload, short circuit and battery over-discharge etc
Advantages
•Miniaturization, tower or rack UPS are available
• Longer backup time and longer using life time
• Frequency adaptation: 50 Hz / 60 Hz
Specification
DPH1-10K-Li UPS(Li-ion Battery Support)Specification
Model | 1KS | 2KS | 3KS | 6KS | 8KS | 10KS | |
Capacity | VA/W | 1kVA/800W | 2kVA/1.6kW | 3kVA/2.4kW | 6kVA/5.4kW | 8kVA/7.2kW | 10kVA/9kW |
Topology | Double Conversion Online UPS | ||||||
Phase | Single Phase Input Single Phase Output | ||||||
Mains Input | Wiring | L/N+PE | |||||
Voltage Range | 90~300VAC | ||||||
Frequency Range | 40Hz-70Hz | ||||||
Input Power Factor | ≥0.99 | ||||||
AC Output | Wiring | L/N+PE | |||||
Output Voltage | 208/220/230/240VAC | ||||||
Voltage Regulation | ±1% | ||||||
Output Frequency | 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run) | ||||||
Waveform | Sine Wave | ||||||
Distortion (THDV%) |
<2%(Linear Load) | ||||||
<7%(None-Linear Load) | |||||||
Over load capability | 1Min@105%~125%Rated Load 30Sec.@125%~150%Rated Load 0.5Sec.@>150%Rated Load |
10Min@105%~125%Rated Load 1Min@125%~150%Rated Load 0.5Sec.@>150%Rated Load |
|||||
Efficiency | AC/AC Mode | 86% | 87% | 89% | 91% | 92% | 93% |
DC/AC Mode | 85% | 86% | 87% | 90% | |||
Battery & Charger |
Rated Battery Voltage | 24VDC200WH 48VDC400WH 48VDC600WH | 192VDC | ||||
Battery Capacity | External Battery (long time) Standard |
||||||
Backup Time | |||||||
Charging Current | 6A/10A(Option) | ||||||
Charging Voltage | 56.4V(default) / Adjust according to battery request | ||||||
Charger Behavior & Protection |
CC. CV. Floating. Turn-Off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
||||||
HMI | LCD Display | Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status | |||||
Communication Interface | RS232 /MODBUS(option)/Dry Contact (option) | ||||||
Ethernet Port (Option) | Support remote monitor the UPS via Smart Phone APP , Web page, PC Monitor Software , Support Server / NAS shutdown | ||||||
Operating Environment Endurance |
Temperature range | -10~50oC | |||||
Relative Humidity | 0-98%(Non-condensing) | ||||||
Acoustics Noise |
<55dB @ 1 meters |