Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Still deciding? Get samples of US$ 500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | 1K | 2K | 3K | 6K | 10K | ||
Phase | Single phase with ground | ||||||
Input | |||||||
Rate capacity | 1KVA/800W | 2KVA/1.6KW | 3KVA/2.4KW | 6KVA/4.8KW | 10KVA/8KW | ||
Rate voltage | 110/115/120/127VAC or 220/230/240VAC | 220/230/240VAC | |||||
Turn on voltage range | 55-150VAC or 110-300VAC ≤50% load | 110-300VAC ≤50% load | |||||
85-140VAC or 160-280VAC ≤100% load | 176-300VAC ≤100% load | ||||||
Frequency range | 40~70Hz | 46~54Hz or 56~64Hz | |||||
Power factor | ≥0.99 100% load | ||||||
Output | |||||||
Rate voltage | 110/115/120/127VAC or 220/230/240VAC | 220/230/240VAC | |||||
Voltage regulation | ±1% | ||||||
Line mode frequency | 47~53Hz or 57~63Hz | 46~54Hz or 56~64Hz | |||||
Bat mode frequency | 50Hz or 60Hz | ||||||
Voltage harmonic | ≤3% R load | ≤3% R load | |||||
≤6% RCD load | ≤5% RCD load | ||||||
Crest ration | 3:01 | ||||||
Line-Bat transfer | 0ms | ||||||
INV-Bypass transfer | ≤4ms | 0ms | |||||
Over load | 105%±5%<load≤125%±5%:1min;125%±5%< load ≤150%±5%:30s;load>150%±5%:300ms; ( transfer to bypass and alarm) | ||||||
Efficiency | |||||||
Line mode | > 88% | > 88% | > 90% | > 92% | > 93% | ||
Bat mode | > 83% | > 85% | > 88% | > 90% | > 91% | ||
Bat | |||||||
Number | 2 | 4 | 6 | 16 or 20 | |||
Charger voltage | 27.4VDC | 54.7VDC | 82.1VDC | 218.4VDC/273VDC | |||
Charge current (stand) | 1A | 1A/2A | |||||
Charge current(long) | 1A/2A/4A/6A(adjustable,20Bat can't select 6A) | ||||||
Size(length*width*height)and weight | |||||||
Stand UPS(mm) | 282*145*220 | 397*145*220 | 421*190*318 | 369*190*688(6K 16 No.)/ | |||
442*190*688 | |||||||
Weight(kg) | 9.8 | 17 | 27.6 | 61 | 74 | 66 | 76 |
Long time UPS(mm) | 282*145*220 | 397*145*220 | 369*190*318 | 442*190*318 | |||
Weight(kg) | 4.1 | 6.8 | 7.4 | 12 | 16 | ||
Environment | |||||||
Work temperature | 0ºC~40ºC | ||||||
Work humidity | 20%~95% | ||||||
Audible noise | ≤50dB | ≤55dB | ≤58dB | ||||
Communication | RS-232/USB/SNMP card adjustable |