• Online Double Conversion Low Frequency UPS Single Phase in Single Phase out
  • Online Double Conversion Low Frequency UPS Single Phase in Single Phase out
  • Online Double Conversion Low Frequency UPS Single Phase in Single Phase out

Online Double Conversion Low Frequency UPS Single Phase in Single Phase out

Phase: Three Phase
Type: On-line
Protection: Overvoltage
Application: Defence
Classification: Lighting/Power
Standby Time: Standard Machine
Samples:
US$ 500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
31DPL100K-S
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Daopulse
Input Frequency Range
40~70Hz
Line-Bat Transfer
0ms
Inv-Bypass Transfer
0ms
Communication
RS-232/USB/Snmp Card
Transport Package
Standard Exporting Packing
Specification
940*567*1015mm
Trademark
Daopulse
Origin
Guangzhou, China-Mainland
HS Code
8504402000
Production Capacity
500000 Pieces/Year

Product Description

online double conversion low frequency UPS single phase in single phase out
Main Features

· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the ≤2%   R load;   ≤4%   RCD load
· Wide input voltage and frequency range,400VAC(three phase with ground) ,40~70Hz
· 0ms Line-Bat transfer , ensure the safety and reliablity of load. 
· ECO mode optional, reduce the  UPS power consumption. 
· Low audible noise (below ≤70dB), will not affect your daily life. 
Product Details
Online Double Conversion Low Frequency UPS Single Phase in Single Phase out

Specifications
Model 100K 120K 160K 200K
Phase  
Input
Rate capacity 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW
Rate voltage 400VAC(three phase with ground)
Turn on voltage range  208-478VAC(three phase)  ≤70% load
305-478VAC(three phase)  ≤100% load
Frequency range 40~70Hz
Output
Rate voltage 380/400/415VAC(three phase)  ±1%
Line mode frequency 46~54Hz or 56~64Hz
Bat mode frequency 50Hz or 60Hz
Voltage harmonic ≤2%   R load;       ≤4%   RCD load
Crest ration 3:01
Line-Bat transfer 0ms
INV-Bypass transfer 0ms
Over load (Line mode) 100%~110%:1H;110%~125%:10min;125%~150%:1min;load>150%:200ms; ( transfer to bypass and alarm)
Over load (BAT mode)
Frequency
Line mode > 94%
Bat mode > 93%
Bat
Number 32~40(adjustable)
Charger voltage +/-13.7VDC×BAT NO.
Charge current (stand) No
Charge current (long) 24A 32A 40A 48A
Size(length*width*height)and weight
Stand UPS(mm) No
Weight(kg)
Long time UPS(mm) 940*567*1015 1040*567*1452
Weight(kg) 199 234 306 340
Environment
Work temperature 0ºC~40ºC
Work humidity 20%~95%
Audible noise ≤70dB ≤73dB
Communication RS-232/USB/SNMP card