Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
• Advanced DSP digital control technology
The most advanced and powerful 32bit DSP professor within the international market
Fit for control system deal with complex, high precision, high speed, high real-time
performance. It will be more reliable
• Environmental
The product will not cause harm to the environment and people under normal use
• Active power factor correction
Digital PFC and most advanced soft switch technology, input power factor up to 99%,
energy saving and reduce the system cost
• 0 ms transfer time from line to battery mode
When the line abnormal, UPS turn to battery mode among 0ms,
it effectively ensures the safety and reliability of the load
• 0.9 load power factor
Satisfied with most equipment, increase the UPS load ability
Model | DPH33 30K | DPH33 40K | DPH33 60K | DPH33 80K | |||||
Phase | Three phase in /Three phase out | ||||||||
Input | Rate capacity | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | 80KVA/72KW | ||||
Rate voltage | 400Vac(three phase with ground) | ||||||||
Turn on voltage | 190-520Vac(three phase) ≤50% load | ||||||||
305-478Vac(three phase) ≤100% load | |||||||||
Frequency range | 46~54Hz or 56~64Hz | ||||||||
Output | Rate voltage | 380/400/415Vac (three phase) ±1% | |||||||
Line mode frequency | 46~54Hz or 56~64Hz | ||||||||
Bat mode frequency | 50Hz or 60Hz | ||||||||
Harmonic | ≤2% linear load; ≤4% non-linear load | ||||||||
Crest ration | 3:1 | ||||||||
Transfer | 0ms | ||||||||
Overload (Line mode) | 100%~110%: 10min; 110%~130%: 1min; load>130%: 1s; ( transfer to bypass and alarm) |
||||||||
Overload (BAT mode) | 100%~110%: 30s; 110%~130%: 10s; load >130%: 1s; ( transfer to bypass and alarm) |
||||||||
Efficiency | Line mode | > 94% | |||||||
BAT mode | > 93% | ||||||||
BAT | Number | 32~40(adjustable) | |||||||
Charge voltage | +/-13.7V×BAT NO. | ||||||||
Charge current (stand) | 2A(only 32 BAT) | No | |||||||
Charge current (long) | 1A/2A/3A/4A can be set | 2A/4A/6A/8A can be set | |||||||
Size (D*W*H mm) | Stand UPS | 815*300*1000 | No | ||||||
Longtime UPS | 815*300*1000 | 790*360*1010 | |||||||
Weight (kg) | Stand UPS | 225 | 250 | No | |||||
Longtime UPS | 60 | 61 | 108 | 113 | |||||
Environment | Audible noise | ≤60dB | ≤70dB | ≤75dB | |||||
Temperature / Humidity | 0ºC~40ºC;20%~95% | ||||||||
Communication | RS-232/USB/SNMP card |