Industrial True on Line Double Convertion 3 Phase UPS 1kVA - 200kVA

Phase: Three Phase
Type: On-line
Protection: Overvoltage
Application: Defence
Classification: Lighting/Power
Standby Time: Standard Machine
Samples:
US$ 500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
DPH3/3 10KVA
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Daopulse
Input Frequency Range
46~54Hz or 56~64Hz
Line-Bat Transfer
0ms
Efficiency
> 94%
Weight
225kg/60kg
Transport Package
Standard Exporting Packing
Specification
790*360*1010mm
Trademark
Daopulse
Origin
Guangzhou, China-Mainland
HS Code
8504402000
Production Capacity
500000 Pieces/Year

Product Description

Industrial true on line double convertion 3 phase ups 1KVA - 200KVA

Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 VAC --240 VAC, 40 -- 70 Hz.
· 0ms Line-Bat transfer, ensure the safety and reliability of load. 
· ECO mode optional, reduce the  UPS power consumption. 
· Low audible noise (below 50 dB), will not affect your daily life. 


Specfictations 
Model 30K 40K 60K 80K 100K 120K 160K 200K
Phase Three phase in--Three phase out
Input
Rate capacity 30KVA/27KW 40KVA/36KW 60KVA/54KW 80KVA/72KW 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW
Rate voltage 400VAC(three phase with ground)
Turn on voltage range  190-520VAC(three phase)  ≤50% load 208-478VAC(three phase)  ≤70% load
305-478VAC(three phase)  ≤100% load 305-478VAC(three phase)  ≤100% load
Frequency range 46~54Hz or 56~64Hz 40~70Hz
Output
Rate voltage 380/400/415VAC(three phase)  ±1%
Line mode frequency 46~54Hz or 56~64Hz
Bat mode frequency 50Hz or 60Hz
Voltage harmonic ≤2%   R load;       ≤4%   RCD load
Crest ration 3:01
Line-Bat transfer 0ms
INV-Bypass transfer 0ms
Over load (Line mode) 100%~110%:10min;110%~130%:1min; 100%~110%:1H;110%~125%:10min;125%~150%:1min;load>150%:200ms; 
( transfer to bypass and alarm)
load>130%:1s; ( transfer to bypass and alarm)
Over load (BAT mode) 100%~110%:30s;110%~130%:10s;load >130%:1s; 
 ( transfer to bypass and alarm)
Frequency
Line mode > 94%
Bat mode > 93%
Bat
Number 32~40(adjustable)
Charger voltage +/-13.7VDC×BAT NO.
Charge current (stand) 2A(only 32 BAT) No
Charge current (long) 1A/2A/3A/4A can be set 2A/4A/6A/8A can be set 24A 32A 40A 48A
Size(length*width*height)and weight
Standard UPS(mm) 815*300*1000 No
Weight(kg) 225 250
Long time UPS(mm) 815*300*1000 790*360*1010 940*567*1015 1040*567*1452
Weight(kg) 60 61 108 113 199 234 306 340
Environment
Work temperature 0ºC~40ºC
Work humidity 20%~95%
Audible noise ≤60dB ≤70dB ≤75dB ≤70dB ≤73dB
Communication RS-232/USB/SNMP card